Poor Deck and Stair Construction Can Kill

In a recent article published in The Los Angeles Times, July 6th of this year, a tragic deck collapse resulting in serious injury and death, is reported. The deck was part of a three story apartment complex in a Birmingham suburb. Seven party-goers is all it took to create this tragic event. Unfortunately, this is an all to common occurrence now days. Reports are continually surfacing, confirming the growing frequency of these serious, life threatening collapses.

Over the past several years, much has been done to address deck and stair safety issues, but we still have a long way to go. One glaring example of the failure in deck and stair safety protocol is the industry standard of permitting "hot dipped galvanized" anchors, screws, hangers and other hardware to be in direct contact with ACQ, pressure treated wood. The galvanic corrosion created between the high copper content of the wood and the galvanizing is so severe that the normal industry standard of G90 galvanizing will corrode in as little as 12 months and G185, such as Z-Max® can be gone in 24 months. The industry (including code officials) has adopted G185 as a fall back position with no engineering testing available to substantiate the validity or longevity of this adoption...this is a "knee jerk" reaction and is an accident waiting to happen. Without a barrier between the pressure treated wood and galvanized hardware, serious corrosion is inevitable.

Take for example the new NADRA (North American Deck and Railing Association) study that examined the number of injuries caused by outdoor deck stairs and porches from 2003 to 2007. The report confirms that deck and stair injuries are on the increase. NADRA points to a 2003 study showing a total of 37,760 injuries which required a visit to the hospital. Of these injuries, 6,120 were a result of structural failure or collapse. Further, the report shows that by 2007, the incidents of serious injury had risen to 55,160. Quoting from the report- "Nearly 15% of all injuries are a result of structural failure". Wood decks are constantly exposed to the elements and they have a limited life span of 10-15 years. As you can see, important to have your deck and deck stairs inspected so that signs of wood decay and deterioration can be repaired.

Other codes address "rail post support" safety. A rail post per code regulations is required to support a lateral load of 200 lbs. This is a poorly enforced area of the code and with many inspectors content with the bump test. If it doesn't move too much when they bump it with their hip, the rail will pass inspection. Many rail posts are simply lagged or nailed to the rim joists and post which are mounted directly to the deck surface will simply not meet code. The tragedy is, there are systems available on the market that correctly address this problem. Simpson, USP and Deck-Loc have brackets which will meet code for rim joist attachment but there's only one adjustable bracket system (discussed below) which will meet code for wood or composite stairs.

Attention is now being given to the ability of the vertical post's strength when hit by various degrees of lateral thrust pressure. These new directives, requiring the vertical rail post to support a minimum of 200 lbs. of lateral thrust, is making engineered stair systems extremely popular, with their ability to withstand over 500 lbs of lateral thrust for the 'rail post support' structural sections of the overall decking plans.

Stairs are perhaps the most overlooked area of construction. Stairs using standard cut stringers have been used for eons and are "grandfathered" into code as accepted construction. Stringers are cut from 2x12's and greatly weakened in the process. Several stringers are then run longitudinal down length of the stair to make up for the strength loss during cutting. Long stair run tend to bounce and stringer failure is not uncommon. Additionally, many of these stairs are built without risers which is a "child safety" issue in many states. General Contractor and renowned professional deck builder, Pat Noonan of Minnesota says, "Of the 50+ decks I have torn off and replaced, not one had a stair system that outlasted the deck." The majority of them had shaky, unsafe stairs, and it was the main reason they were doing the rest of the deck."

Engineered stair systems such as adjustable bracket systems for wood stair and composite stairs overcome many of these problems and safety issues. This is due to the much more rigorous testing required to gain ICC/ES acceptance for a stair system which has not been simply "grand fathered" into common use. This adjustable bracket system is engineered in a completely different manner to conventional stair construction. These adjustable steel brackets lock the risers and treads onto the stringers, with a solid, joist hanger type connection. Only two stringers are required for stairs up to 7' in width. This becomes possible because the two outside stringers are full depth, acting like beams running down the length of the stair ( only three end are cuts required per stringer). Next, the risers (which are locked to the steel brackets) span across the stair like joist hangers, at each step supporting the tread.

The result is a "rock solid" stair which has been tested at over 1,200 lbs. per sq. ft.(uniform distributed load), well in excess of the code requirement of only 100 lbs per sq. ft. (commercial load). The steel brackets adjust to form any rise or run required and are powder coated over a hot dipped galvanized finish. The powder coating (paint) sets up an effective barrier between the pressure treated wood and the galvanized finish, preventing corrosion. Additionally the structural risers overcome the child safety issue (found on stairs without risers) and as mentioned above, the brackets have been tested to exceed code requirements for lateral load applied to "rail post" supports.

General Contractor Pat Noonan continues, "Craftsmanship will only take you so far when you are dealing with a inferior framing system and components. When deck builders notch steps out of a 2"x12", they are cutting all the strength out of the wood and putting the entire weight of the stair plus anyone walking up or down on 4" of wood left in the 2"x12". With an adjustable bracket system, they are putting the weight on 11' of solid wood- there's no comparison".

EZ Stairs adjustable bracket stair system allows builders to construct stairs with a wide range of materials such as redwood, cedar, tropical wood, treated wood, untreated wood, vinyl, steel, and composites. This stair system allows for customized rise and treads configurations which can be adjusted to meet all building codes for any interior or exterior application- ICC approved. It is the only adjustable stair bracket system available anywhere. The EZ Stairs system will allow you to build strong, easy to install stairs, in less time and with less money than traditional construction. You will have stairs that will last for many years longer than conventional stair construction.To help you figure out how many stairs you will need, the website provides a free stair calculator.

Tag : stair lifts,stair desigh,stair railing

Article Source: http://EzineArticles.com/?expert=Richard_Truckner

Wednesday, 10 June 2009

Building Deck Stairs on a Budget - By Richard Truckner / Leslie ...

As a professional, I’ve built many decks of all sizes and shapes. Stairs are often the last part of the deck to be tackled because they are usually the most difficult and expensive part of the deck to build. However, by using a method known as the ‘engineered bracket system’, not only can I save up to $500 per flight of wood stairs, but the installation is easy, with professional results.


The adjustable stair bracket system automatically adjusts to the exact rise and run needed. The customized rise and treads configurations can be adjusted to meet all building codes for any interior or exterior application. The brackets act as joist hangers which allow the stair risers to be used structurally, carrying the load across the stair like floor joists. Using only two outside stringers, the stair width can be up to nine feet wide and the stairs are strong. The need for interior stringers is eliminated. The outside stringers then require only 3 to 4 cuts each, and the risers and treads are simply attached to the brackets. If you make a mistake, you can readjust the brackets.


A wide range of materials such as redwood, cedar, tropical wood, treated wood, untreated wood, vinyl, steel, and composites can be used. Adjustable brackets allow for customized rise and tread configurations which can be adjusted to meet all building codes for any interior or exterior application.


This is how it works: Set the brackets on the two 2×6 stringer members using the spacers and pivot screws. Remove spacers and rotate brackets to adjust stair height. Fix brackets in position, attach risers and treads. 3D video demos are available on the website below.


Before you begin, determine the material you are going to use, the exact number of steps you need and the stair width.


You will need (2) 2×6’s per stringer for each side. Make sure when you purchase your 2×6’s make sure that they are straight without any twist. The 2×6’s will need to be at least 12″ longer than the total length of your stairs. Two stringers are sufficient to span up to 7′ wide (exterior stair requirements).


For risers you will use 2×8’s for riser heights up to 7-1/4″ and 2×10’s for higher risers. For treads you can use 2×12’s (which is the easiest option). However, if you decide to use (2) 6 inch wide treads instead…wood or composite, you will need to use cleat brackets to bridge between the risers for tread support. Time saving tip: when you determine how many steps you will need and your stair width….get all your risers and treads pre-cut to exact lengths when you purchase the materials.


Tools/Materials needed will be: a power drill, saw (skill saw is preferable, but not required, #8 1 1/4″ Phillips flat head or star/square drive screws for the stair brackets, #8 2 1/2″ deck screws for every 9″ of tread and riser connection and Spacers for customized riser and tread measurements.


The “Engineered Stair Bracket System” method eliminates the need to cut stringers and is tested to be much stronger and faster than conventional construction. Whether you’re a seasoned professional or a do-it-yourselfer, you will build fast, strong and accurate stairs, on a budget.


EZ Stairs is the only adjustable, engineered stair bracket system available anywhere, ICC approved. It won Pro Sales Magazine’s Editor’s 2004 Choice award for new product innovation in construction. EZ Stairs’ composite deck stairs compatibility solution was chosen for LBM Journal’s ‘Hot Products’ Award at the 2005 and 2008 International Builders Show. Easy installation, strong and professional. The system is engineered so that even someone with minimal building skills, can build stairs easily, and pros can just build faster- equaling more profit. For more information, visit the ez-stair.com website, or call 866-693-9570. See an EZ Stairs 3D demo and photos.


About the Author

Richard Truckner, holder of 12 plus patents in construction related products. Bachelor of Technology in Architecture; career spanning 40 plus years. Richard is the inventor of EZ Stairs.

http://www.articlerich.com/blog/home-improvement/building-deck-stairs-on-a-budget-by-richard-truckner-leslie-walker

Friday, 17 December 2010

Building Deck Stairs on a Budget

As a professional, I've built many decks of all sizes and shapes. Stairs are often the last part of the deck to be tackled because they are usually the most difficult and expensive part of the deck to build. However, by using a method known as the 'engineered bracket system', not only can I save up to $500 per flight of stairs, but the installation is easy, with professional results.

The adjustable stair bracket system automatically adjusts to the exact rise and run needed. The customized rise and treads configurations can be adjusted to meet all building codes for any interior or exterior application. The brackets act as joist hangers which allow the stair risers to be used structurally, carrying the load across the stair like floor joists. Using only two outside stringers, the stair width can be up to nine feet wide and the stairs are strong. The need for interior stringers is eliminated. The outside stringers then require only 3 to 4 cuts each, and the risers and treads are simply attached to the brackets. If you make a mistake, you can readjust the brackets.

A wide range of materials such as redwood, cedar, tropical wood, treated wood, untreated wood, vinyl, steel, and composites can be used. Adjustable brackets allow for customized rise and tread configurations which can be adjusted to meet all building codes for any interior or exterior application.

This is how it works: Set the brackets on the two 2x6 stringer members using the spacers and pivot screws. Remove spacers and rotate brackets to adjust stair height. Fix brackets in position, attach risers and treads. 3D video demos are available on the website below.

Before you begin, determine the material you are going to use, the exact number of steps you need and the stair width.

You will need (2) 2x6's per stringer for each side. Make sure when you purchase your 2x6's make sure that they are straight without any twist. The 2x6's will need to be at least 12" longer than the total length of your stairs. Two stringers are sufficient to span up to 7' wide (exterior stair requirements).

For risers you will use 2x8's for riser heights up to 7-1/4" and 2x10's for higher risers. For treads you can use 2x12's (which is the easiest option). However, if you decide to use (2) 6 inch wide treads instead...wood or composite, you will need to use cleat brackets to bridge between the risers for tread support. Time saving tip: when you determine how many steps you will need and your stair width....get all your risers and treads pre-cut to exact lengths when you purchase the materials.

Tools/Materials needed will be: a power drill, saw (skill saw is preferable, but not required, #8 1 1/4" Phillips flat head or star/square drive screws for the stair brackets, #8 2 1/2" deck screws for every 9" of tread and riser connection and Spacers for customized riser and tread measurements.

The "Engineered Stair Bracket System" method eliminates the need to cut stringers and is tested to be much stronger and faster than conventional construction. Whether you're a seasoned professional or a do-it-yourselfer, you will build fast, strong and accurate stairs, on a budget.

Article Source: http://EzineArticles.com/?expert=Richard_Truckner

Wednesday, 2 February 2011

New Stair Construction Building Codes and Tougher 2009 Code Enforcement Laws - What You Need to Know

The construction industry is entering a time of rapid change. New and existing codes relating to stair construction safety are now being enforced. Since safety will no longer be compromised, deck builders will have to confront the age old problem of making a deck safe when it comes to attaching posts to deck platforms, let alone attaching posts to deck stairs. Important issues such as, Child Safety, the American Disability Act (ADA) requirements and many new building materials are major elements driving new stringent code enforcement. This is why it is so important to protect yourself and your livelihood by making sure you are aware of the latest laws and compliance issues related to stairs. If a safety problem arises due to stair construction or compliance, it's not enough to say "I wasn't aware of the new laws." It's your responsibility to be aware and know of issues that could involve the safety of your family, friends, employees -- and potentially millions of dollars.

The number of deck injuries and fatalities have been increasing at a dramatic rate. Between 2000 - 2008, 30 deaths were reported as a direct result of collapse. This number does not include injuries. Statistics show that when a deck collapses that there is a 75% chance of severe injury and possible fatality. You can be proactive and check your deck for wobbly railings, rotted boards, cracks, missing and loose connections.

Stair Injuries: The most serious stair injuries being documented are the direct result of stair rail collapses. This shouldn't come as a surprise, because until just recently, no product or system has complied with the minimum code requirements for 'rail post support' on wood stairs.

Lack of Code Enforcement: There are many reasons one could assume why this important code violation has slipped through the enforcement cracks. Commonly, when stairs are built and ready for inspection, code officials will use the quick 'tug' & 'pull' test, if minimal amount of deflection is evident, then the stairs, will more than likely, pass. To officially comply with the existing stair rail post support code, all stair rail posts must withstand a 200 lbs. lateral load. It's a serious challenge to accurately 'on-site' determine structural integrity in relation to stair rail post support. However "Tort" protection for the building departments, still places the "liability issues" squarely on the shoulders of business & property owners.

The problem: Traditional stair construction using cut out stringers or commonly used stair angles, do not have the rigidity to hold 200 lbs. lateral load (applied to the post) as required by code. Until recently, there has never been an easy or satisfactory solution for building rail post supports that are strong, and meet building code requirements as well.

The Simple Solution: Rail posts can be used with adjustable stair brackets that have been engineered to achieve the required lateral load. This combination has been tested and proven to withstand 200 lbs. lateral load and 500 lbs. ultimate load as required by code- a first in the industry.

Article Source: http://EzineArticles.com/?expert=Richard_Truckner

Friday, 15 August 2008

Simplifying Stair Rise And Run Calculations

When I first started my career in carpentry, building a set of stairs seemed like a complicated and daunting task. We're not talking finished oak, curved or spiral staircases. I'm talking about your normal carpet covered straight run staircases or porch and deck staircases.


My first stair building experience sort of took the mystery out of it all. I didn't have to do much figuring because it was a deck replacement job. All I did was save the old stringers from the demo of the old deck. In doing so it all started to make sense to me. How the stairs were attached, the width of the treads, and how high each step was became less of a secret to me.


Anyone with the courage to take on this job needs only patience, basic math, a framing square and the ability to stand back and look at the big picture.


The first thing I look at is how high it is to the top of the landing or deck the stairs will be rising to. A comfortable step is in the 7 to 8 inch range. With this in mind I divide the height to the landing by seven. If the height to the landing is 70" then it will take 10 rises to get to the top of the landing. I used 70" to simplify this example. Ninety-nine times out of a hundred it will be 7" and some odd fraction. For instance if the height was 73 1/2", the rise would be 7 1/2".


When building stairs there is always one less tread than there is risers. In this case with 10 risers, that means there are 9 treads. When cutting my stringers, I like to make the cuts for my treads 10" long. At this dimension I can use a 2x12 for treads without ripping them to a narrower width. This gives me a nosing or overhang of 1 1/4". It also makes it easier to figure out how much room the stairs will require. In this case 9 treads X 10" = 90". The total run of the stairs is 90".


An example of how easy this works are stairs that go from the 1st floor to the 2nd floor of a house with an eight foot ceiling. This takes 14 risers at 7 and 5/8 inches (I've cut so many of these it is forever imbedded in my mind). This means there are 13 treads. Thirteen times ten is 130". I always made my stairwell opening 120". This lets 10" of the stringer (a full tread) sit on the deck or concrete floor. It also leaves plenty of headroom for the stairs below if there is a basement. The same well opening above (120") also gives you enough headroom.


This can seem like an overwhelming project. Like any other project, if you take the time and patience and a little thought you can acquire the ability.


(c) 2005 Mike Merisko


Published At: www.Isnare.com